-40%
TLC5000 24hr 12-channel/Lead ECG/EKG Holter Monitor System PC Software Analysis
$ 263.47
- Description
- Size Guide
Description
PM10TLC5000 24H 12-channel ECG/EKG System Holter Software,US
Description
Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
11)One-key print, convenient and fast to print the reports.
12)Perfect case management function.
13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia.
14)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
15)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
Performance
Lead: standard 12-lead
Record time: 24-hour
Power supply: two “AA” batteries
Interface: USB2.0
Calibration voltage: 1mV±5%
Noise level: ≤30μV
CMRR: ≥60dB
Low-frequency characteristics: time constant≥3.2s
Scan speed: 25mm/s±5%
Polarizing voltage: ±300mV, sensitivity: ≤±10%
Minimum measure signal: 50 µV p-p
Accessories
Lead cable (1 set)
ECG electrode (1 bag)
USB cable(1)
Disk(1)
Bag(1)
User manual(1)
Physical characteristic
Dimension: 111mm(L) × 60mm(W) × 25mm(H)
Weight: about 105g(without batteries)
Payment
1.Paypal
2.Bank transfer
Shipping
1. For your earlier and safer to receive the item, please leave us your detail address and telephone number.
2. Your item will be sent via Air mail within 48 hours after payment is received. The shipping time may is around 2-4 weeks.
For item In US warehouse,To US buyer,ship by FedEx 2-5 days delivery.
3. As the usual way, buyer is responsible for the duties, taxes or other VAT or extra charges from the import countries.
4.All items will be shipped to buyer's PayPal address. Please confirm your PayPal address is correct before purchase.
International Buyers - Please Note:
? Import duties, taxes are not included in item price or shipping charges. These charges are buyer's responsibility.
? Please check with your country's customs office to determine what these additional cost will be prior to bidding
Terms of Sale
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved
Feedback
Please leave me a positive feedback if you are satisfied with our products, Your positive feedback will be appreciated,thank you.
If you have any problems, please contact us asap before you open a case and leave a negative feedback or ship the item back,
we promise we will give you a satisfied answer, thank you for your understanding!
Return - After service
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 years warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the item.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with its original package and accessories. Customer is responsible for shipping charges on returned items.
About Us
Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.
At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products.We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
Contact Us
Contact Person:Vivian Zhang
Contec Medical Systems Co.,Ltd, Manufacturer, Qinhuangdao, China
Address(US):1440 Chase Avenue,Elk Grove Village,Illinois 60007 United States
Only English User Manual,Please contact us if you need other language manual.